Field of Application
Coarse-grained Suevit-Trass lime plaster for filling and levelling unevenness in the substrate. Suitable as a base coat / finishing render for exterior and interior masonry.Material Properties
- High water vapour permeability
- Weather resistant
- Frost resistant
- Can be processed by hand and machine
- Easily feltable
- Non-combustible
Material Base / Vehicle
Natural hydraulic lime, trass and mineral aggregates according to DIN EN 13139Packaging/Package Size
Bag 30 kgColours
Light brown (tan)
Storage
Dry, protected from moisture, in original sealed packaging.Application within 12 months.
Technical Data
Normal plaster mortar (GP) according to DIN EN 998-1
Reaction to fire: Class A1 according to DIN EN 13501-1 (non-combustible)
■ Heat conductivity: λ10 dry, mat ≤ 0.61 W/(mK) for P=50% according to
DIN EN 1745
■ Water vapour permeability: μ ≤ 20 according to DIN EN 1015-19
■ Compressive strength: Category CS I according to DIN EN 998-1 0,4 N/mm2 -
2,5 N/mm2 according to DIN EN 1015-11
■ Adesive tensile strength: ≥ 0,30 N/mm according to DIN EN 1015-12 break
pattern B
■ Capillary water absorption: Category WC1 according to DIN EN 998-1 C ≤
0.40 kg/(m2-min0.5) according to DIN EN 1015-18
Maximum particle (grit) size
approx. 4 mmDensity
ρ: approx. 1.64 g/cm³ according to DIN EN 1015-10Suitability according to Technical Information No. 606 Definition of Application Areas
Interior 1 | Interior 2 | Interior 3 | Exterior 1 | Exterior 2 |
+ | + | + | + | + |
(–) not suitable / (○) conditionally suitable / (+) suitable |
Suitable Substrates
Suitable for old and new masonry.Preparatory work
Mask window sills and add-on parts.
Carefully cover glass, ceramic, clinker, natural stone, painted, glazed and anodised surfaces.
Substrate Preparation
The substrate must be firm, load-bearing, frost-free and free of adhesion-reducing substances. Base coats must be well set and roughened. Clean the substrate thoroughly. Pre-wet absorbent substrates (matt damp). Apply a half-covering coat of Histolith® Trass-Vorspritzputz and allow to harden until lightly dry.
VOB Part C, DIN 18350 must be observed.
Preparation of Material
- 30 kg of material (one bag) in approx. 6.5 litres of water.
The material can be mixed with a powerful, slow-running agitator or compulsory mixer with
mixer and with clean, cold water to form a lump-free mass.
Work through again after approx. 3-5 minutes. If necessary, adjust the consistency with a little water after this maturing time.
Depending on the weather, the working time is approx. 2 hours (pot life).
Do not use water to make material that has already hardened workable again.
Method of Application
Apply the material to the prepared substrate to a thickness of 15-20 mm, roughen the surface after application. After sufficient drying time, a second layer of render can be applied using the same material.
If a felted surface is to be created, Histolith® Feinputz or Histolith® Renovierspachtel can be applied and felted after sufficient drying time.
Layer Thickness
Outside: 15-20 mm
Inside: 10-15 mm
Two-layer application: up to 40 mm
Surface Coating System
On exterior surfaces a finishing coat with highly water vapour permeable paint is essential.Therefore Histolith® Dispersionssilikatfarben (emulsion silicate paints) and Histolith® Kalkfarben (lime paints) are recommended.
Consumption
- approx. 1.4 kg/m2 per mm layer thickness
These consumption figures are approximate values.
Deviations depending on the property or processing must be taken into account.
Application Conditions
During the application and curing phase, the ambient and substrate temperatures must not be
substrate temperatures must not be below +5 °C and above +30 °C. Do not apply under direct
Do not apply in direct sunlight, strong wind, fog or high humidity.
Please refer to the leaflet "Rendering, thermal insulation, levelling, coating at high and low
temperatures" from the the Bundesverband Ausbau und Fassade.
In unfavourable weather conditions, suitable measures must be taken to protect the facade surfaces.
Drying/Drying Time
The waiting time for reworking depends on temperature, humidity, air movement, sunlight and
application thickness. The information is therefore intended as a guide.
Waiting time:
- Standard value 1 day per mm layer thickness
During the drying period, the treated surfaces must be protected from drying out quickly.
Tool Cleaning
Rinse with water immediately after use, observing the legal requirements.Special Risks (Hazard Note) / Safety Advice (Status as at Date of Publication)
Causes skin irritation. Causes serious eye damage. If medical advice is needed, have product container or label at hand. Keep out of reach of children. Do not breathe dusts or mists. Wash skin thoroughly after handling. Wear protective gloves/ eye protection. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor.Disposal
Can be landfilled after concentration, when in compliance with local regulations.
Giscode
ZP 1Further Details
See Material Safety Data Sheet (MSDS).Other Notes
According to Directive 2003/53/EC amending Council Directive 76/769/EEC the EU limit value of soluble chromium VI (< 0,0002 % soluble chromium VI of the total dry weight of the cement) can not be guaranteed to be kept below, after 12 months of storage.Customer Service Centre
Tel.: +49 6154 71-71710Fax: +49 6154 71-71711
e-mail: kundenservicecenter@caparol.de
International Distribution: Please see www.caparol.com